Sendzimir galvanised steel insulation bolt W-MID
Insulation drift W-MID
DWL-(W-MID)-(HDG)-D30MM-(0-40)-8X90
Register now and access our wide range of products
- Surface of head suitable for use as a plaster base
- Knock-in shaft has the design of a clamping sleeve and braces along the entire installation depth in the drill hole
- When attaching soft insulation materials that are not self-supporting, the insulation disc is simply pushed onto the insulation bolt
Fire resistance (anchoring base: Concrete ≥ B35): F120: For securing wood-wool multilayer panels (100 mm)
Fire resistance (anchoring base: Concrete ≥ B35): F120: For securing wood-wool multilayer panels (100 mm)
Datasheets(X)
- For attaching hard and soft insulation materials, e.g. mineral wool, polystyrene, sandwich panels, cork on concrete, solid brick masonry, lightweight concrete, perforated brick masonry
- For use in push-through installation
Anchor diameter | 8 mm |
Anchor length (l) (l) | 90 mm |
Disc diameter | 30 mm |
Nominal drill-bit diameter (d 0) | 8 mm |
Embedding depth (h nom) | 50 mm |
Type description | W-MID |
Material | Steel |
Max. attachment height (t fix) | 40 mm |
Centre-to-centre distance (a) | 160 mm |
Edge clearance (a r) | 80 mm |
Minimum component thickness (h min) | 100 mm |
Drill hole depth (h 1) - condition | Depending on anchor length and insulation thickness |
Surface | Sendzimir galvanized |
Performance data | |||
Anchor diameter [mm] | 8 | ||
Recommended tensile load | Concrete ≥ B25 | Frec [kN] | 0,2 |
Solid calcium silicate block | 0,2 | ||
Masonry brick | 0,2 | ||
Vertically perforated brick | 0,05 | ||
Hollow calcium silicate block | 0,05 | ||
Recommended shear load | Concrete ≥ B25 | Frec [kN] | 0,25 |
Solid calcium silicate block | 0,25 | ||
Masonry brick | 0,25 | ||
Vertically perforated brick | 0,1 | ||
Hollow calcium silicate block | 0,15 |